| Key features | |
| IFOV (spatial resolution) | 1.86 mRad, D:S 532:1 |
| Infrared resolution | 320 x 240 (76,800 pixels) |
| Field of view | 34.1 °H x 25.6 °H |
| Focus system | Fixed |
| Minimum focus distance | 46 cm (18 in) |
| Ruggedized display | 3.5 inch (8.9 cm landscape) 320 x 240 LCD |
| Ergonomic design | Designed for one-handed use |
| Temperature measurement | |
| Temperature range (not calibrated below -10 °C) | -20 °C to 400 °C (-4 °F to 752 °F) |
| Accuracy | ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
| Thermal sensitivity (NETD) | ? 0.045 °C at 30 °C target temp (45 mK) |
| On-screen emissivity correction | Yes (both value and table) |
| On-screen reflected background temperature compensation | Yes |
| On-screen transmission correction | No |
| Wireless connectivity | |
| Wireless connectivity | Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi and LAN (where available) |
| Fluke™ Connect app compatible | Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing |
| Fluke Connect Assets optional software | Yes*, assign images to assets and create work orders. Easily compare measurement types - whether mechanical, electrical or infrared images - in one location |
| IR Fusion® technology | |
| IR Fusion® technology | Yes |
| AutoBlend™ mode | Yes |
| Picture-In-Picture (PIP) | Yes |
| Built-in digital camera (visible light) | 5MP |
| Level and span | |
| Level and span | Smooth auto and manual scaling |
| Fast auto-rescale in manual mode | Yes |
| Minimum span (in manual mode) | 2.5 °C (4.5 °F) |
| Minimum span (in auto mode) | 5 °C (9.0 °F) |
| Data storage and image capture | |
| Extensive memory options | Internal 4GB memory and 4GB micro SD card |
| Image capture, review, save mechanism | One-handed image capture, review, and save capability |
| Image file formats | Non-radiometric BMP or JPEG or fully-radiometric is2 |
| Memory review | Yes |
| Software | Fluke Connect desktop software - full analysis and reporting software with access to the Fluke Connect system |
| Analyze and store radiometric data on a PC | Yes |
| Export file formats with Fluke Connect software | is2, BMP, GIF, JPEG, PNG, TIFF |
| Voice annotation | 60 seconds maximum recording time per image; reviewable playback on camera; Bluetooth headset required (sold separately) |
| IR-PhotoNotes | Yes - 3 images |
| Auto capture (temperature and interval) | Yes |
| Battery | |
| Batteries (field-replaceable, rechargeable) | Two lithium ion smart battery pack with five-segment LED display to show charge level |
| Battery life | 4 hours continuous use per battery pack |
| Battery charging time | 2.5 hours to full charge |
| Battery charging system | Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter |
| AC operation | AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
| Power saving | User selectable |
| Color palettes | |
| Standard palettes | 8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
| Ultra contrast palettes | 8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra |
| General specifications | |
| Laser pointer | Yes |
| Frame rate | < 9 Hz or 30 Hz |
| Color alarms | High temperature, low temperature, isotherms (within range) |
| Infrared spectral band | 7.5 ?m to 14 ?m |
| Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
| Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) without batteries |
| Relative humidity | 10 % to 95 %, non-condensing |
| Center-point temperature measurement | Yes |
| Spot temperature | Hot and cold spot markers |
| User-definable spot markers | 3 |
| User defined measurement boxes | Expandable-contractible measurement box |
| Hard case | Rugged hard carrying case with soft transport bag, including adjustable strap |
| Safety standards | IEC 61010-1: Overvoltage category II, Pollution Degree 2 |
| Electromagnetic compatibility | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A |
| Australian RCM | RCM IEC 61326-1 |
| US FCC | EN61326-1; FCC Part 5, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3 |
| Vibration | 2G, IEC 68-2-6 |
| Shock | 25G, IEC 68-2-29 |
| Drop | Engineered to withstand 2 meter (6.5 feet) drop |
| Sized (H x W x L) | 26.7 cm x 10.1 cm x 14.5 cm (10.5 in x 4.0 in x 5.7 in) |
| Weight (battery included) | 0.72 kg (1.6 lb.) |
| Enclosure rating | IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
| Warranty | Two-years (standard) |
| Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
| Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
| RoHS compliant | Yes |
- 320 x 240 resolution
- 2 meter drop test
- IR Fusion™ technology for context
- Fixed focus
- Measure up to 400 °C
- Subject to Export Control

AMPROBE
BAUR
BW Technologies
Cirrus
CorDEX
ELCOMETER
emt
EXTECH INSTRUMENTS
FLIR
Fluke
FLUKE calibration
Honeywell
isa
Kestrel
KYORITSU
MEGGER
Morehouse
MTD
ndb
Planck VISION SYSTEMS
RAE SYSTEMS
SMC
Tektronix
TENTECH
TESA TECHNOLOGY
Time Electronics
ue SYSTEMS INC